Letter to the editor regarding “Two-year results of a double-blind multicenter randomized controlled non-inferiority trial of polyetheretherketone (PEEK) versus silicon nitride spinal fusion cages in patients with symptomatic degenerative lumbar disc disorders”
Letter to the Editor

Letter to the editor regarding “Two-year results of a double-blind multicenter randomized controlled non-inferiority trial of polyetheretherketone (PEEK) versus silicon nitride spinal fusion cages in patients with symptomatic degenerative lumbar disc disorders”

Roel F. M. R. Kersten1,2, F. Cumhur Öner2, Mark P. Arts3, Marian Mitroiu4, Kit C. B. Roes5, Arthur de Gast1, Steven M. van Gaalen1,6

1Clinical Orthopedic Research Center – midden Nederland (CORC-mN), Department of Orthopedics, Diakonessenhuis Utrecht/Zeist, The Netherlands; 2Department of Orthopedics, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands; 3Department of Neurosurgery, Haaglanden Medical Center, The Hague, The Netherlands; 4Department of Biostatistics and Research Support, Clinical Trial Methodology, Julius Centre for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands; 5Department of Health Evidence, Section Biostatistics, Radboud University Medical Center, Radboud University, Nijmegen, The Netherlands; 6Spinecenter.Amsterdam, Orthopedics, Acibadem International Medical Center, Amsterdam, The Netherlands

Correspondence to: Roel F. M. R. Kersten, MD. University Medical Center Utrecht, Department of Orthopedics, Heidelberglaan 100, 3584CX, Utrecht, The Netherlands. Email: rfmrkersten@gmail.com.



Submitted Jan 22, 2021. Accepted for publication May 12, 2021.

doi: 10.21037/jss-21-6


Unpleasantly surprised we read the study by McEntire, Maslin and Bal (1). As the principal investigators of this study, comprising of the surgeons and staffs of the participating hospitals, we did not authorize the authors to publish these results. We strongly disagree with the post-hoc analysis performed by the authors, and therefore terminated our prior collaboration with McEntire et al. during the review process of this study. The correct version of the manuscript, discussing the authentic one and two-year results of our RCT, has recently been published in The Global Spine Journal (2). The original protocol criteria were used to analyze these results, published in 2014 (3).

McEntire and Bal are involved in SINXT Technologies (formerly known as Amedica), the manufacturer of the silicon nitride interbody cage. Our collaboration with Amedica started in 2011 with the design of the Silicon Nitride versus Peek (SNAP) trial, resulting in a joint publication of the SNAP research protocol (3). Furthermore an in vivo caprine study of silicon nitride versus PEEK cages was published with mutual consent (4). Amedica acted as the sponsor of these studies. An independent clinical research organization (CRO) managed the clinical trial together with the principal investigator’s institutions. After analyzing the one and two-year results of our clinical RCT, we concluded there is insufficient evidence that the silicon nitride cage is non-inferior to the PEEK cage, using the original protocol criteria. Amedica (now called SINXT Technologies) disagreed, and presented a biased post-hoc analysis confirming the non-inferiority of silicon nitride compared to PEEK. Also, they excluded the principal investigators to publish their view of the results of the RCT by claiming exclusive rights for the study data. With this act, the authors did not adhere to the ethical and moral standards of Evidence Based Medicine (EBM). Firstly, they acted contrary to article 36 of the Declaration of Helsinki, stating “Negative and inconclusive as well as positive results must be published or otherwise made publicly available”. Also, restricting the principal investigators to publish the authentic results is deemed to be unreasonable according to the involved Medical Ethics Committee (METC) Directive on the Assessment of Clinical Trial Agreements. Moreover, the authors did not adhere to the revised International Committee of Medical Journal Editors (ICMJE) criteria. Lastly, it discloses a case of plagiarism by copying large parts of the Introduction, Methods, Results and Discussion sections combined with the figures and tables of the principal investigators (2).

Methodologically, their post-hoc analysis approach is a clear case of incorrect scientific practice. The design of the study (3), including the non-inferiority margin and assumptions, provided ample opportunity to challenge the margin and assumptions prior to having access to unblinded data and results. This did not happen, it only occurred at the moment the authors were fully aware of complete results. Their reasoning on what constitutes a non-inferiority margin is flawed: this margin is not the minimal clinically important difference (MCID) at individual patient level, but a margin that ensures non-inferiority at population level, as well as that it is sufficiently small to be robust against constancy of effects over time (5,6). Likewise, statistical power assessments at the design stage include that the standard deviation is not fixed but is estimated from the data. Post-hoc “power” calculations based on the observed standard deviation can be done, but they do not constitute an assessment of power of the study (7,8). The post-hoc analysis is fully data driven, therefore actual type 1 error (significance level) cannot be assessed and is likely inflated. The possibility to evaluate the primary results against any other non-inferiority margin than pre-defined is already perfectly possible based on our published paper (2) and does not justify an independent paper.

The EBM primary goal is to increase our scientific knowledge in order to improve public health and patients’ care. However, SINXT Technologies did not act in the patients’ best interest. In our opinion they have shown to be an unreliable partner and potentially damaged the public debate about interactions between commercial entities and research institutions. We strongly urge the editor to remove the publication of McEntire et al. from the Journal of Spine Surgery and all publicly available platforms and when deemed necessary take any further legal steps.


Acknowledgements

Funding: None.


Footnote

Provenance and Peer Review: This article was a standard submission to the journal. The article did not undergo external peer review.

Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at http://dx.doi.org/10.21037/jss-21-6). RFMRK, MPA and SMG report that the SNAP trial was financially supported by Amedica. The other authors have no conflicts of interest to declare.

Ethical Statement: The authors are accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.

Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0/.


References

  1. McEntire BJ, Maslin G, Bal BS. Two-year results of a double-blind multicenter randomized controlled non-inferiority trial of polyetheretherketone (PEEK) versus silicon nitride spinal fusion cages in patients with symptomatic degenerative lumbar disc disorders. J Spine Surg 2020;6:523-40. [Crossref] [PubMed]
  2. Kersten RFMR, Öner FC, Arts MP, et al. The SNAP Trial: 2-Year Results of a Double-Blind Multicenter Randomized Controlled Trial of a Silicon Nitride Versus a PEEK Cage in Patients After Lumbar Fusion Surgery. Global Spine J 2021; Epub ahead of print. [Crossref] [PubMed]
  3. Kersten RF, van Gaalen SM, Arts MP, et al. The SNAP trial: a double blind multi-center randomized controlled trial of a silicon nitride versus a PEEK cage in transforaminal lumbar interbody fusion in patients with symptomatic degenerative lumbar disc disorders: study protocol. BMC Musculoskelet Disord 2014;15:57. [Crossref] [PubMed]
  4. Kersten RFMR, Wu G, Pouran B, et al. Comparison of polyetheretherketone versus silicon nitride intervertebral spinal spacers in a caprine model. J Biomed Mater Res B Appl Biomater 2019;107:688-99. [Crossref] [PubMed]
  5. Non-Inferiority Clinical Trials to Establish Effectiveness. Guidance for Industry. Center for Biologics Evaluation and Research. Food and Drug Administration. 2016; Available online: https://www.fda.gov/media/78504/download
  6. Guideline on the choice of the non-inferiority margin. EMEA/CPMP/EWP/2158/99. 2005; Available online: https://www.ema.europa.eu/en/documents/scientific-guideline/guideline-choice-non-inferiority-margin_en.pdf
  7. Althouse AD. Post Hoc Power: Not Empowering, Just Misleading. J Surg Res 2021;259:A3-A6. [Crossref] [PubMed]
  8. Zhang Y, Hedo R, Rivera A, Rull R, Richardson S, Tu XM. Post hoc power analysis: is it an informative and meaningful analysis? Gen Psychiatr 2019;32:e100069 [Crossref] [PubMed]
Cite this article as: Kersten RFMR, Öner FC, Arts MP, Mitroiu M, Roes KCB, de Gast A, van Gaalen SM. Letter to the editor regarding “Two-year results of a double-blind multicenter randomized controlled non-inferiority trial of polyetheretherketone (PEEK) versus silicon nitride spinal fusion cages in patients with symptomatic degenerative lumbar disc disorders”. J Spine Surg 2021;7(2):249-251. doi: 10.21037/jss-21-6

Download Citation